SIMATIC ET 200SP – The powerful IO system for compact control cabinets

Highest flexibility and strongest performance
The innovative I/O system SIMATIC ET 200SP convinces through maximum usability, particularly compact design, and impressive performance. Thanks to our constant exchange with users from all over the world and all sectors, we were able to design SIMATIC ET 200SP even more practical and user-friendly.
Simple and profitable - the decentralized periphery for the future
SIMATIC ET 200SP is your automation solution for the requirements of the coming years: extremely easy to install and extremely user-friendly, the SIMATIC ET 200SP impresses with its reliability and safety in continuous operation.
Your outstanding advantages:
- Free choice of the PROFINET connection technology via bus adapter
- No tools needed for wiring due to push-in technology
- Improved accessibility of the wiring thanks to a new arrangement of the spring NC contacts and the associated conductor opening
- Extremely clear arrangement thanks to colored labels and reference labeling plates and labeling strips
- Channel-specific diagnostic functions
Enormous performance in a small space
With SIMATIC ET 200SP, you can optimally use the space in your control cabinet: the system is about 50% narrower than comparable distributed peripherals, but with a height of approx. 115 millimeters it offers space for 16 channels with single-line connection (without AUX terminals). For a 3-wire connection, the height is 140 mm for 8 channels.
Your space advantage:
- Expandability of the station to 64 modules
- Space savings in the control cabinet
- Compact dimensions, suitable for 80 mm standard control boxes
At the forefront in terms of performance
Despite its compact design, SIMATIC ET 200SP is one of the most powerful decentralized peripherals - communicative, safe and efficient.
Your benefits during operation:
- Fast communication via PROFINET
- Modules and terminal boxes can be replaced while system is running (“hot swapping”)
- Uniform shielding concept, from the conductor, terminal box and back plane bus to the PROFINET cable
- Greater energy efficiency thanks to system-integrated PROFIenergy
- AS-Interface
- Configuration control via software
SIMATIC ET 200SP - the communication talent
SIMATIC ET 200SP adapts to your communication standard:
The range of supported communication paths, be it via interface modules / bus adapters or communication modules leaves nothing to be desired
- Fast communication via PROFINET with isochronous backplane bus as standard
- PROFIBUS, the proven fieldbus standard as an alternative
- With AS-Interface, sensors and actuators of the lowest field level can be easily and quickly interlocked and connected to the SIMATIC ET 200SP
- IO-Link ensures a uniform connection of switching devices, sensors or RFID devices to the control level via a cost-effective point-to-point connection
Distributed controller based on SIMATIC ET 200SP
The distributed controllers ET 200 CPUs combine compactness and flexibility. Especially in the medium performance range for machines with distributed intelligence or series machines with limited space, the distributed controllers are the perfect solution for standard and fail-safe applications.
The CPUs have the same functionalities as the CPU 1511 / CPU 1513 of the S7-1500 controller family, such as the CPU. For example, the integrated trace function, integrated system diagnostics, integrated security, web server or full symbolic programming.
Thanks to the I-Device functionality, the connection to a higher-level CPU can be carried out in exactly the same way as with a standard interface module. The ET 200SP station is distinguished by a noise-resistant design thanks to short signal and encoder wiring and low wiring effort.
The CPUs support additional functions such as PROFIenergy, isochronous mode, configuration control (option handling) and DP master.
Two interface modules with integrated CPU and PROFINET connection are available for SIMATIC ET 200SP.
With the 3 integrated Ethernet ports, the connection adapters can be flexibly selected with the bus adapters.
SIMATIC ET 200SP - CPU 1510SP-1PN
The CPU 1510SP-1 PN is the low-cost entry-level CPU for applications with medium processing and response speed requirements in discrete manufacturing technology. The CPU 1510SP-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as a 3-port switch so that a line structure can be established in the plant via ports 1 and 2 and also a PG / PC or HMI device can be connected via port 3.
SIMATIC ET 200SP - CPU 1512SP-1PN
The CPU 1512SP-1 PN is the CPU for applications with medium demands on the processing performance and the reaction speed in the discrete manufacturing technology. The CPU 1512SP-1 PN can be used as PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as a 3-port switch so that a line structure can be established in the plant via ports 1 and 2 and also a PG / PC or HMI device can be connected via port 3.
The failsafe ET 200SP CPUs enable standard and safety program processing. They are certified to EN 61508 (2nd Edition) for Functional Safety and are suitable for use in safety-related applications up to SIL 3 according to IEC 62061 and PL e according to ISO 13849.
The 151xSP F CPUs can be expanded with ET 200SP standard and fail-safe modules as well as decentrally via PROFINET / PROFIsafe with any ET 200 systems.
For IT security, additional password protection has been set up for F configuration and F program
SIMATIC ET 200SP - CPU 1510SP- F1PN
The CPU 1510SP F-1 PN is the reasonably priced entry-level CPU for standard and fail-safe applications with medium demands on processing performance and reaction speed in discrete manufacturing technology. The CPU 1510SP F-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as a 3-port switch so that a line structure can be established in the plant via ports 1 and 2 and also a PG / PC or HMI device can be connected via port 3.
SIMATIC ET 200SP - CPU 1512SP- F1PN
The CPU 1512SP F-1 PN is the CPU for standard and fail-safe applications with average demands on processing performance and reaction speed in discrete manufacturing technology. The CPU 1512SP F-1 PN can be used as a PROFINET IO controller or as distributed intelligence (PROFINET I-Device). The integrated PROFINET IO IRT interface is designed as a 3-port switch so that a line structure can be established in the plant via ports 1 and 2 and also a PG / PC or HMI device can be connected via port 3.
SIMATIC ET 200SP Open Controller
he SIMATIC ET 200SP Open Controller is the first controller of this type to combine the functions of a PC-based software controller with visualization, PC applications and central I/Os in a compact device.
The already installed and preconfigured SIMATIC S7-1500 Software Controller, the PC-based version of SIMATIC S7-1500, is used for control. This controller is operated independently of Windows and thus ensures high system availability. This facilitates the controller's rapid start-up and supports Windows updates and reboot during ongoing operation. Even a failure of Windows does not have any impact on the controller.
The SIMATIC ET 200SP Open Controller is available in two device generations:
- CPU 1515 SP PC in standard and failsafe version
- CPU 1515 SP PC2 in standard and failsafe version as well as technology CPU and fail-safe technology CPU
SIMATIC ET 200SP Open Controller
The ET 200SP Open Controller comes with a pre-installed software controller or as a complete system with software controller and HMI software.
The SIMATIC ET 200SP Open Controller provides know-how and access protection and features important automation functions, for example for axis positioning, integrated system diagnostics or interfaces to Profinet.
The open controller is flexibly expandable by ET 200SP modules and is optimized for series machine manufacturing as well as for machines with distributed architecture.Thanks to its compact design, the ET 200SP Open Controller requires only minimum space and can be accommodated in compact control boxes directly on the machine.
The SIMATIC ET 200SP Open Controller allows for the realization of automation solutions with a particularly favorable cost-performance ratio. For instance, visualization can be simply realized via a SIMATIC Industrial Flat Panel connected via the graphics interface, optionally also with multitouch functionality. For commissioning purposes, mouse and keyboard can be directly connected via USB interfaces. At the same time, the Gigabit Ethernet interfaces support high-performance connection to higher-level networks.
"All in one"
- Controller with central I/Os
- Visualization and Windows applications
- PC interfaces for monitor, mouse and keyboard
- Gigabit-EthernetHigh system availability
- Software Controller independent of Windows
- Support of Windows restart during ongoing controller operationCompact and modular
- Small footprint
- Comprehensive portfolio of I/O modules
- Single-line expansion with up to 64 moduleRuggedness
- Continuous operation at ambient temperatures of 60°C without power loss
- Zero maintenance through fan-free design
- High EMC compatibility
- Resistance to vibration and shock loadsUser-friendly design
- Externally accessible bulk memory - protected against unauthorized access
- Integrated run/stop switch for the controller
- Additional memory capacity via SD card
- PROFINET onboard: Replaceable bus adapter for flexible connectionEfficient engineering in the TIA Portal
- no Windows settings for the software controller required
- Reusability of S7 programs on other hardware platforms
SIMATIC ET 200SP Open Controller
The ET 200SP Open Controller is a robust, compact control system that combines the function of an ET 200SP controller with a PC-based platform. The controller can be used to control special and series machines or even decentrally to control systems.
The I / O modules of the ET 200SP can be plugged in centrally and communicate via the integrated backplane bus. S7 communication can be set up via the PROFINET adapters of the ET 200SP system and decentralized peripherals can be connected. The PROFIBUS CM DP module extends the CPU 1515SP PC with a PROFIBUS communication.
For additional HMI functionality, the CPU 1515SP PC + HMI with preinstalled WinCC Runtime Advanced is offered.
Portfolio with CPU 1515SP PC2
The second-generation ET 200SP Open Controller comes with a pre-installed software controller or as a complete system with software controller and HMI software. The operating system is Windows 10 IoT Enterprise 64 bit.
Portfolio with CPU 1515SP PC
The ET 200SP Open Controller comes with a pre-installed software controller or as a complete system with software controller and HMI software. The operating system is Windows Embedded Standard 7 (32-bit or 64-bit versions).
SIMATIC ET 200SP Open Controller with Safety Integrated
The SIMATIC ET 200SP open controller with failsafe functionality is a PC-based controller in the design of the ET 200SP I/O system. Here, too, the pre-installed S7-1500 software controller is used as failsafe version with Safety Integrated. The integrated safety function makes the system very compact and saves space in the control cabinet because the additional safety controller that is usually required is not necessary here. Its compact design and modular expansion option make this controller particularly well suited for series production of machinery.
Portfolio with CPU 1515SP PC2 F
The failsafe ET 200SP Open Controller of the second generation is supplied with a pre-installed failsafe software controller or as a complete system with software controller and HMI software. The operating system is Windows 10 IoT Enterprise 64 bit.
Portfolio with CPU 1515SP PC F
The ET 200SP Open Controller Failsafe comes with a pre-installed fail-safe software controller or as a complete system with software controller and HMI software. The operating system is Windows Embedded Standard 7 (32-bit or 64-bit versions).
SIMATIC ET 200SP Open Controller with technology functions
The range of SIMATIC S7-1500 T-CPUs will be expanded with the CPU 1515SP PC2 T and CPU1515SP PC2 TF Open Controllers, which combine standard, safety and motion control functionality in one device. These are based on the new hardware of the CPU 1515SP PC2 Open Controller, and thus combine the advantages of advanced motion control functionality with an integrated Windows environment.
Previous motion control functions, such as absolute gearing and camming, are now joined by kinematics control with up to four interpolating axes as required, for example, for pick-and-place tasks. The system offers predefined kinematics, such as cartesian portals, roller pickers, SCARA robots, and delta pickers. A free transformation interface allows seamless integration into the user’s kinematics.
Users parameterize the kinematics with a graphically supported and intuitively operable configuration editor, and program the movements in space in the usual SIMATIC STEP 7 programming environment via standardized function modules in accordance with PLCopen.
In combination with the servodrive systems SINAMICS V90 (with Profinet), SINAMICS S210, and SINAMICS S120 even sophisticated motion control tasks can be accomplished efficiently
Interface module IM 155
The ET 200SP is connected to the bus system via the interface module. Either PROFINET interface modules or PROFIBUS interface modules can be selected.
Interface modules to PROFINET
The interface modules (IM) for PROFINET contain a 2-port switch for easy structure of a line structure. With PROFINET, more parameters are possible per station and thus more highly functional modules can be used. In case of service, the IM can be replaced without the use of a programming device - device name and parameters remain on the module. As with the PROFIBUS variants, the interface modules for PROFINET are separated from the interface module and the connection module. Various connection technologies are available for the interface module IM154-4 PN HF with the proven M12 7/8 "connection and the connection with push-pull technology
Interface module to PROFIBUS
The interface modules (IM) for PROFIBUS can be combined with three different modules for connecting bus and power supply.All connection modules for PROFIBUS have visible address adjusters to easily recognize the address and a switchable terminating resistor.The integrated T functionality allows the commissioning of sub-segments and an uninterrupted bus communication in case of service.
SIMATIC ET 200SP - Bus Adapter -Flexibility in choosing connection technology
Some interface modules of the SIMATIC ET 200SP have a universal PROFINET interface for Bus Adapters. With the appropriate BusAdapter, the type of connection can be adapted to the requirements of the respective application.
An overview of the essential properties of the PN interfaces is shown in the table below:
Bus Adapters can be used as integrated media converters changing from fiber-optic cables to copper. Two socket types for the fiber optics cables are offered supporting SC-RJ or LC plugs.
Bus Adapters with SC-RJ sockets
- BusAdapter BA SCRJ/RJ45
Media converter
2 Ports (Switch) 1 x SCRJ fiber optic / 1 x RJ45 copper
6ES7193-6AP20-0AA0 in the Industry Mall
6ES7193-6AP20-0AA0 in the Tia Selection Tool
- BusAdapter BA SCRJ/FC
Media converter
22 Ports (Switch) 1 x SCRJ fiber optic / 1 x Fast Connect copper
6ES7193-6AP40-0AA0 in the Industry Mall
6ES7193-6AP40-0AA0 in the Tia Selection Tool
BusAdapter with LC sockets
- BusAdapter BA LC/RJ45
Media converter
2 Ports (Switch) 1 x LC multimode fiber optic / 1 x RJ45 copper
6ES7193-6AG20-0AA0 in the Industry Mall
6ES7193-6AG20-0AA0 in the Tia Selection Tool
- BusAdapter BA LC/FC
Media converter
2 Ports (Switch) 1 x LC multimode fiber optic / 1 x Fast Connect copper
6ES7193-6AG40-0AA0 in the Industry Mall
6ES7193-6AG40-0AA0 in the Tia Selection Tool
SIMATIC ET 200SP - Signal Modules
Scalable and cost-optimized configuration of a ET 200SP station is achieved by a comprehensive portfolio of Peripheral Modules. there are digital and analog IO modules, as well as Communication and Technology Modules.
SIMATIC ET 200SP is about 50% narrower than other distributed peripheries. With its height of 115 millimeters, the system can accommodate 16 channels with single-wire connection (without AUX-plugs). For a 3-wire connection with AUX-plugs the height for 8 channels is 140 millimeters. The depth is 75 millimeters. In order to keep its small size, the power module for load group formation is integrated into the system of SIMATIC ET 200SP.
The peripheral modules are labelled with different colored squares to identify easily the type of module.
Digital Input Module (DI) 8/16 channels , Color white
Digital Output Modules (DQ) 4/8/16 channels, Color black
Analog Input Modules (AI) 4 channels, Color light blue
Analog Output Modules (AQ) 2/4 channels, Color dark blue
Digital Input Modules (DI)
The distributed I/O system ET 200SP offers a comprehensive portfolio of digital inputs, modules with standard functionality (ST) as well as enhanced functions
(HF High Feature / HS High Speed)
Especially for price sensitive applications there are modules available that offer basic functionality (BA).
Digital Inputs for NAMUR sensors and modules for AC voltage of 120 - 230 V complete the portfolio.
The most common modules are also available in packs of ten, which avoids packaging material and speeds up unpacking
Enhanced functions with diverse modules
Counting for DI 8x24VDC HS
4 channels for the connection of electronic pulse generators are available in the mode counting with a counting breadth of 32 bits and a maximum frequency of 10 kHz. Extensive parameterization options permit adaptation to the application (upper and lower counter limit, choice flanks, these are counted, 2 reference values to set a status bit, input delay).
MSI - Module internal Shared Input for DI 8x24VDC HF
Input data are provided up to 4 IO controllers. Every controller can grasp it reading on the same channels.
Oversampling for DI 8x24VDC HS
Oversampling – fast equidistant data acquisition or rather issue at moderate CPU-Cycles
Oversampling provides the user with the possibility to determine of two till n readings in synchronous and in constant equal intervals within a PROFINET-Transmit clocking. All n readings collected and transferred then in chronological order for PROFINET-Controller. The readings are available for further evaluation.
Oversampling is always useful to use when measurements in a high temporal resolution should be available, but the application does not require a fast reaction to the single readings. A major advantage of Oversampling is that no faster CPU-Cycle is required for recording the high temporal resolution measurements. Typical applications are usually measurements for the detection of quality data and the collection of accurate position data, from which we can derive precise timing control function later.
The Function Oversampling is also for output data realized. For example the ET 200SP High-Speed-analog module AQ 2xU/I HS analog value can be issued more finely.
The two High speed digital modules DI 8 x24VDC HS and DQ 4 x24VDC are/2 of A HS, completely new in the product line of the SIMATIC ET 200 SP which also supports the mode Oversampling besides another two modes.
Digital Output Modules (DQ)
The distributed I/O system ET 200SP offers a comprehensive portfolio of digital outputs, modules with standard functionality (ST) as well as enhanced functions (HF High Feature / HS High Speed)
Especially for price sensitive applications there are modules available that offer basic functionality (BA)
Digital outputs with AC voltage up to 230V and relay outputs, NO as well as CO - complete the portfolio.
The most common modules are also available in packs of ten, which avoids packaging material and speeds up unpacking.
Enhanced functions with diverse modules
Pulse width Modulation for DQ 4x24VDC/2A HS
The four outputs provide a pulse-width modulated output signal in this mode. The digital channel is steered for with a pulse-/ break pulse duty ratio of 0.0% to 100.0%. The putting signal is issued in the form of an impulse result of one and out switching impulses digitally.
The control of the digital channel is done by a pulse / pause duty cycle, which is cyclically depending on the output value and from which the user program can be updated. The control signal is used as a pulse train by on- and off switching impulse which was digital expensed.
Valve actuation for DQ 4x24VDC/2A HS
A special valve drive function is integrated in the mode DQ. One switches on "1" signal at version a this and the exit for a parameterizable hold time then changes into a pulse break version whose frequency and pulse duty ratio are adjustable. The putting signal is issued in the form of an impulse result of one and out switching impulses digitally
MSI - Module internal Shared Input for DI 8x24VDC
Input data are provided up to 4 IO controllers. Every controller can grasp it reading on the same channels.
Oversampling for DI 8x24VDC HS,
Oversampling – fast equidistant data acquisition or rather issue at moderate CPU-Cycles
Oversampling provides the user with the possibility to determine of two till n readings in synchronous and in constant equal intervals within a PROFINET-Transmit clocking. All n readings collected and transferred then in chronological order for PROFINET-Controller. The readings are available for further evaluation.
Oversampling is always useful to use when measurements in a high temporal resolution should be available, but the application does not require a fast reaction to the single readings. A major advantage of Oversampling is that no faster CPU-Cycle is required for recording the high temporal resolution measurements. Typical applications are usually measurements for the detection of quality data and the collection of accurate position data, from which we can derive precise timing control function later.
The Function Oversampling is also for output data realized. For example the ET 200SP High-Speed-analog module AQ 2xU/I HS analog value can be issued more finely.
The two High speed digital modules DI 8 x24VDC HS and DQ 4 x24VDC are/2 of A HS, completely new in the product line of the SIMATIC ET 200 SP which also supports the mode Oversampling besides another two modes.
Analoge Eingangsmodule (AI)
Das Peripheriesystem ET 200SP bietet ein umfangreiches Spektrum an Analog Eingabebaugruppen, ob mit Standardfunktionalität (ST) oder erweitertem Funktionsumfang (HF High Feature / HS High Speed)
Für preissensitive Anwendungen stehen auch Module mit Basisfunktionalität (BA) bereit.
Neben Spannungs- oder Strommessung werden Module für die Messarten Widerstand, Widerstandsthermometer und Thermoelemente angeboten.
Die gängigsten Module sind auch in Packungen zu 10 Stück erhältlich, das spart Verpackungsmaterial und Zeit beim Auspacken.
Analoge Ausgangsmodule (AQ)
Das Peripheriesystem ET 200SP bietet Analog Ausgabebaugruppen für Aktoren an Strom- oder Spannungsausgängen an.
Module mit Standardfunktionalität (ST) sind mit 2oder 4 Ausgängen lieferbar, Module mit erweitertem Funktionsumfang (HF High Feature / HS High Speed) immer mit 2 Ausgängen.
Die High-Speed Baugruppe AQ 2xUI HS bietet schnelle taktsynchronen Ausgänge und Oversampling Funktionalität.
AI Energy Meter - Energiemessmodul
Mit Hilfe des Energy Meter Moduls können Energie- und Leistungsverbrauch bestimmt werden.
Mithilfe der Varianten in High Feature Ausführung wird es zudem möglich Netzanalysen durchzuführen (Oberwellenanalyse, Summenstrom, Klirrfaktor, Amplitudensymmetrie, …). Zwischen den Betriebsarten „Netzanalyse“ und dem Energiezähler kann ohne Datenverlust dynamisch zur Laufzeit umgeschaltet werden.
Das Energiezählmodul Energy Meter ermöglicht Energiemanagement mit über 200 (ST) bzw. 500 (HF) Energiemesswerten. Datenerfassung elektrischer Kenngrößen in 1- und 3-Phasennetzen bis 400 bzw. 480 VAC mit einer Genauigkeit von +/-0,5%. Die High Feature Variante gibt es in zwei Ausführungen:
CT (Current transformer): Zum Anschluss von Stromwandlern
RC (Rogowski Coil): Zum Anschluss von Strom-Spannungs-Wandlern und Rogowski-Spulen
Diagnose
Überlast (Toleranzwert und Toleranzzeit einstellbar)
Überspannung, Unterspannung
Lastspannung
Oberer Grenzwert, unterer Grenzwert
Definition eigener Limits mit Diagnosealarmen
Sicherheitsgerichtete Kommunikation
Fehlersichere E/A-Module ermöglichen die Einbindung in sicherheitsgerichtete Anlagen mit SIMATIC Safety Integrated.
Die für den fehlersicheren Betrieb erforderlichen Sicherheitsfunktionen sind in die Baugruppen integriert. Die Baugruppen können für Sicherheitskreise bis Kat. 4/ SIL 3 eingesetzt werden.
Für den Anschluss von digitalen Sensoren/Gebern und/oder Lasten/Aktoren stehen zwei digitale E/A-PROFIsafe-Module zur Verfügung.
Zusätzlich gibt es einen F-Switch zum Abschalten von Standard Peripheriebaugruppen und zum sicheren Ansteuern von ET 200pro Motorstartern in Verbindung mit dem ASM 400V Modul.
F-DQ 8x24VDC/0.5A PP High Feature
8 pp-schaltende fehlersichere Ausgänge
Ideal für die einfache und sichere I/O-Kopplung
Zum Schalten von elektronischen, potentialgebundenen Lasten
Kanalgranulare Passivierung
Kanalgranulare Diagnose, sowohl an Baugruppe (LED) als auch im Diagnosepuffer der F-CPU ablesbar
Breite 15 mm
F-AI 4xI 0(4)...20mA 2-/4-wire High Feature
zentraler/dezentraler Einsatz
4 Analogeingänge mit parametierbarem Messbeich 0..20mA oder 4..20mA
max. erreichbare Sicherheitsklassen SIL 3 (gemäß IEC 61508) und PL e (gemäß ISO 13849-1)
Auflösung 16 bit inkl. Vorzeichen
externe Geberversorgung möglich
Diagnose: Versorgungsspannung, Kurzschluss, Kabelbruch
Kanal- und modulweite Passivierung
unterstützt an F-CPUs S7-1200/1500 das Profil "RIOforFA-Safety"
Breite 15 mm
Mehr Flexibilität und Performance dank zusätzlicher Kommunikationsoptionen
Ob als PROFIBUS Master/Slave, Master für die unterschiedlichen unterlagerten Feldbussysteme oder für die direkte Punkt-zu-Punkt Kommunikation: Kommunikationsbaugruppen der ET 200SP erlauben flexible und performante Lösungen innerhalb einer dezentralisierten Architektur.
Serielle Schnittstellenmodul CM PtP
Zur direkten Anbindung von Automatisierungskomponenten über serielle Schnittstelle
Anbindung von Alt- und Fremdsystemen
Anschluss von Datenlesegeräten oder speziellen Sensoren
Verschiedene physikalische Schnittstellen auf einem Modul, wie RS232 und RS422 oder RS485
Vordefinierte Protokolle, wie 3964(R), Modbus RTU oder USS
Applikationsspezifisch erstellte Protokolle, aufbauend auf Freeport (ASCII)
Übertragungsrate max. 115,2 kbit/s
Telegrammlänge max. 2 kbyte, mindestens 2 Telegramme können auf der Baugruppe zwischengespeichert werden (4 kbyte)
Verdrahtung über ET 200SP Standard-BaseUnit Typ A0
CM AS-i Master ST für SIMATIC ET 200SP
Dieser AS-i Master ermöglicht die Integration von einfachen Feldgeräten in das skalierbare dezentrale Peripheriesystem SIMATIC ET 200SP
Für sichere AS-i Ein-/Ausgänge bietet Siemens auch ein fehlersicheresModul
Vorteile
Gute Skalierbarkeit auch für AS-i Anwendungen durch modularen Aufbau
Geringe Baugröße (unser mit Abstand kleinster AS-i Master)
Umfangreiche Diagnosemöglichkeiten
Einfach- und Mehrfachnetze für kleine bis komplexe Anlagen
Erweiterbar auf AS-i Safety
Technische Merkmale
AS-i Master nach Spezifikation V3.0
62 Teilnehmer pro AS-i Master
Übertragung von E/A Signalen im Prozessabbild vergleichbar zu PROFINET
Integrierte Analogwertverarbeitung
AS-i Leitungsdiagnose
IO-Link Master Modul für SIMATIC ET 200SP
Der SIMATIC ET 200SP IO-Link Master basiert auf der aktuellen IO-Link Spezifikation V1.1. Ein daraus resultierender Vorteil, ist die konsistente Speicherung der IO-Link Device Parameter im Master. So werden bei einem Device-Wechsel die aktuellen Parameter automatisch auf das ausgetauschte IO-Link Device übertragen – ohne applikativen Zusatzaufwand durch den Anwender. Als Besonderheit des SIMATIC ET 200SP-IO-Link Mastermoduls werden aber nicht nur die Deviceparameter automatisch gesichert, sondern auch die Masterparameter. Damit ist ein Modultausch, gleich ob Master oder Device, ohne PG und ohne applikative Rücksicherung der Daten möglich.
Einfach breites (15mm) ET 200SP Elektronikmodul
max. Leitungslänge zum IO-Link Device: 20m
4 IO-Link Ports pro Modul
max. 32 Byte Eingangs- und 32 Byte Ausgangsdaten pro Modul, individuell einstellbar über S7-PCT
unterstützt I&M-Daten
unterstützte Übertragungsraten: COM1, COM2 und COM3
Betriebsarten je Kanal: IO-Link, SIO oder deaktiviert; einstellbar über S7-PCT
unterstützt Device und Mastertausch ohne zusätzlichen Programmieraufwand
CM DP - PROFIBUS DP-Master/-Slave
Das CM DP Modul erweitert die CPU 1510SP-1 PN / 1512SP-1 PN um eine PROFIBUS DP-Schnittstelle bis 12 Mbit/s. Damit kann entweder ein unterlagerter oder ein überlagerter PROFIBUS DP-Strang aufgebaut werden. Dadurch ergeben sich folgende Vorteile:
Entlastung der zentralen Steuerung durch dezentrale Vorverarbeitung
CPU 1510SP-1 PN bzw. CPU 1512SP-1 PN im Stand-alone-Betrieb als DP-Master möglich
Kommunikationsmöglichkeiten der ET 200SP-CPU über CM DP Modul:
als Master für PROFIBUS DP nach IEC 61158/EN 50170 für
125 DP Slaves in Bandbreiten von 9,6 kBit/s bis 12 MBit/sals intelligenter DP-Slave für überlagerten DP-Master am
PROFIBUS DPKommunikation mit Programmiergeräten, Bedien- und Beobachtungsgeräten
Kommunikation zu anderen SIMATIC S7-Systemen
Kommunikation zu SIMATIC S5-Automatisierungsgeräten
Optimale Performance für dezentrale technologische Aufgaben
Technologiebaugruppen bieten hardwarenahe Signalvorverarbeitung für schnelles Zählen, Messen und Positionserfassung für unterschiedliche Geber sowie für die präzise Ausgabe von Impulsen.
Technologische Funktionen, wie z. B. Motion Control oder High Speed Counter, sind bereits in die CPUs der SIMATIC S7-1500 integriert und über STEP 7 projektierbar.
Baugruppen sind verfügbar für:
Zählen und Messen
Positionieren
Wäge- und Dosieraufgaben
Nocken- und Messtasteranwendungen
Ladesteuerung
TM Count 1x24V Zählerbaugruppe
Die Zählerbaugruppe TM Count 1x24V erfasst insbesondere schnelle Signale mit hohen Frequenzen und gibt den Zählerstand und die aktuelle Geschwindigkeit an die Steuerung weiter. Die Zählersteuerung über integrierte digitale Eingangs- und Ausgangssignale sorgt für ein präzises Zählergebnis und schnelle Reaktionen an der Anlage. Umfangreiche Parametriermöglichkeiten bieten eine optimale Anpassung an die Aufgabe und entlasten die Steuerung.
TM Posinput 1 Zähler- und Positionserfassungsbaugruppe
Die Zähl- und Positionserfassungsbaugruppe TM PosInput 1 erfasst schnelle Signale mit hohen Frequenzen und gibt Zählerstand oder Position und die aktuelle Geschwindigkeit an die Steuerung weiter. Die Zählersteuerung über integrierte digitale Eingangs- und Ausgangssignale sorgt für ein präzises Zählergebnis und schnelle Reaktionen an der Anlage. Umfangreiche Parametriermöglichkeiten bieten eine optimale Anpassung an die Aufgabe und entlasten die Steuerung.
Die Baugruppe unterstützt die Positionserfassung mit SSI-Absolutwertgebern mit einer Telegrammlänge von 10 bis 40 Bit. Davon sind max. 31 Bit Positionsinformation und die weiteren Bits Status-Informationen des Gebers. Es werden Singleturn- und Multiturn-Geber unterstützt mit einer Taktfrequenz bis zu 2 MHz.
TM Timer DIDQ 10x24V Time-based IO Baugrupppe
Mit der Time-based IO Baugrupppe ET 200SP TM Timer DIDQ 10x24V lassen sich höchste Anforderungen an Präzision und Geschwindigkeit erfüllen, unabhängig von der Performance des Controllers und des Feldbusses.
Time-based IO sorgt dafür, dass Signale präzise eingelesen und ausgegeben werden – auf 1 Microsekunde genau!
Die Baugruppe eignet sich besonders zur Verwendung mit den Technologieobjekten Nocken, Nockenspur und Messtaster
4 digitale Eingänge mit folgenden Funktionen:
- bis zu 2 Zeitstempel pro Zyklus
- 32-fach Oversampling
- Zählfunktion bis 50kHz
- Inkrementalgebererfassung mit 2 phasenversetzten Spuren
- 6 digitale Ausgänge mit folgenden Funktionen:
- bis zu 2 Zeitstempel pro Zyklus
- 32fach Oversampling
- Pulsweitenmodulierte Ausgabe
Typische Einsatzgebiete:
Exakte Definition von Reaktionszeiten, unabhängig vom Applikationszyklus
Nockensteuerwerk
Messtaster
Längenmessung
Dosieren von Flüssigkeitsmengen
Zeitmessung
TM Pulse 2x24V - Ansteuerung von Proportionalventilen und DC-Motoren
Das TM Pulse 2x24V gibt Pulse mit 24V bis zu einem Nennstrom von 2A (zweikanalig) bzw. 4A (einkanalig) aus. Dabei kann das Signalmuster flexibel eingestellt werden, um Schaltventile, Proportionalventile, DC-Motoren oder andere Aktoren besonders genau anzusteuern. Die maximale Ausgabefrequenz beträgt 100 kHz.
Die Baugruppe verfügt über unterschiedliche Betriebsarten
PWM: Pulsweitenmoduliertes Ausgangssignal, z.B. zum direkten Betreiben eines Proportionalventils, bei Bedarf mit überlagertem Dithersignal für optimale Regelung, optional mit Stromregelung
DC-Motor: Betrieb eines DC-Motors ohne weiteres Leistungsteil, Geschwindigkeitssteuerung durch PWM-Signal mit Drehrichtungsumkehr
Ein-/Ausschaltverzögerung: Durchreichen eines Signals am Digitaleingang auf den Digitalausgang, Möglichkeit zu µ-sekundengenauer Verzögerung der steigenden und fallenden Flanke
Impulskette: Ausgabe einer Impulskette mit definierter Anzahl der Impulse
Einzelimpuls: Ausgabe eines Einzelimpulses mit genau definierter Länge, bei Bedarf durch Digitaleingang gestartet
Weitere Eigenschaften:
Zwei unabhängig voneinander parametrierbare und steuerbare Kanäle
Genau geplante Ausgabesequenzen
Höhere Maschinengeschwindigkeit durch einstellbare, kürzeste Reaktionszeiten ohne zusätzliche Anforderungen an die CPU
Direktes Ansteuern von Aktoren bis zu 4A durch Parallelschaltung der beiden Kanäle
Schrittmotorsteuerung TM StepDrive 24...48V/5A (Fa. Phytron)
Das TM StepDrive Modul der Phytron GmbH ist eine hochgenaue Schrittmotorsteuerung mit integrierter Leistungsendstufe für den Einsatz im dezentralen Peripheriesystem SIMATIC ET 200SP. Es stellt das Nachfolgemodell des 1-Step-Drive für die SIMATIC ET 200S dar.
Das Modul kann zusammen mit System- und IO-Komponenten des dezentralen Peripheriesystems ET 200SP genutzt werden. Der Betrieb ist möglich hinter folgenden Kopfbaugruppen:
- IM PROFIBUS
- IM PROFINET
- ET 200SP CPU
Haftungsausschluss:
Diese Informationen und Beschreibungen wurden mit großer Sorgfalt zusammengestellt. Eine Überprüfung der Vollständigkeit, Richtigkeit, und Aktualität der von den Product Partnern gelieferten Daten ist Siemens jedoch nicht möglich. Es ist daher nicht ausgeschlossen, dass einzelne Daten unrichtig, unvollständig oder nicht aktuell sind. Dieser Beitrag enthält Adressen von Webseiten Dritter. Siemens übernimmt für die Inhalte dieser Webseiten weder eine Verantwortung, noch macht Siemens sich diese Webseiten und ihre Inhalte zu eigen, da Siemens die dort dargestellten Informationen nicht kontrolliert und für die dort bereit gehaltenen Inhalte und Informationen auch nicht verantwortlich ist. Deren Nutzung erfolgt auf eigenes Risiko des Nutzers.
Ladecontroller TM ECC 2x PWM ST
SIMATIC Electrical Charge Controller sind die zentralen Komponenten in Ladeinfrastruktur-Lösungen zum konduktiven Laden von Elektrofahrzeugen.
Folgende Funktionen werden erfüllt:
Detektion des Ladekabels und dessen zulässiger Stromtragfähigkeit
Übermittlung des maximalen Ladestroms der Ladestation an das Elektrofahrzeug
Auswertung der vom Elektrofahrzeug zurückgemeldeten Zustände:
- Ready for charging
- Charging
- Charging with ventilationAnsteuerung des Lastabgangs
Ansteuerung der Steckerverriegelung
Auswertung des Zustandes der Steckerverriegelung oder des Lastschützes·
Die kompakte Bauform auf Basis der SIMATIC ET 200SP ermöglicht den Aufbau von kostenoptimierten und platzsparenden Ladeinfrastruktur-Lösungen.
Der Lade-Controller SIMATIC ET 200SP TM ECC 2xPWM ST ist zur Ansteuerung von Ladeabgängen gemäß IEC 61851 ausgelegt und parametriebar.
SIWAREX WP321 ist ein vielseitiges und flexibles Wägemodul, zur nahtlosen Integration einer statischen Waage in das Automatisierungsumfeld SIMATIC.
Die Wägeelektronik ist innerhalb der Systemreihe SIMATIC ET 200SP integriert und nutzt alle Features eines modernen Automatisierungssystems, wie die integrierte Kommunikation, Bedienen und Beobachten, das Diagnosesystem und die Projektierungswerkzeuge im TIA-Portal, SIMATIC Step 7, WinCC flexible und PCS7
Motorstarter SIMATIC ET 200SP
Mit nur 30mm Baubreite erhalten Sie einen kompakten und leistungsstarken Motorstarter - mit vier Einstellbereichen bis 5,5 kW.
Er ist Teil des dezentralen Peripheriesystems SIMATIC ET 200SP und ist als Standard und Safety Variante erhältlich. Beim Starten von 1- und 3-phasigen Motoren schützt der Starter zuverlässig vor Überlast und Kurzschluss.
Zudem profitieren Sie von einer schnellen Projektierung im TIA Portal.
Ventilinsel AirLINE SP (Type 8647) von Bürkert Fluid Control Systems
Für den Einsatz in ET 200SP steht die Ventilinsel AirLINE SP (Typ 8647) mit diversen Pneumatik Funktionalitäten zur Verfügung.
Die Ventilinsel ist ein Produkt des Product Partners* Bürkert Fluid Control Systems, und nur von Bürkert Fluid Control Systems beziehbar. Diese kann in Verbindung mit System- und IO-Komponenten des dezentralen Peripheriesystems ET 200SP genutzt werden.
Hinweis zu Product Partner
* Product Partner sind externe Firmen außerhalb der Siemens AG und ihrer verbundenen Unternehmen. Informationen und Beschreibungen zu Produkten der Product Partner sind unverbindlich und liegen in der Verantwortung der Product Partner. Diese Produkte werden selbstständig und eigenverantwortlich vom jeweiligen Product Partner hergestellt und von ihm zu seinen Geschäfts- und Lieferbedingungen vertrieben und geliefert.
Soweit nicht gesetzlich zwingend, übernimmt Siemens für diese Produkte und für die Verbindung mit diesen Produkten der Product Partner keinerlei Haftung oder Garantie.
Bitte beachten Sie auch den Haftungssauschluss unten.
Anwendungsbereich
Ventilinseln sind in der industriellen Automatisierung weit verbreitet und dienen als Vorsteuerventile zur Ansteuerung von Aktoren im Bereich der Lebensmittel-, Pharma- oder Wasseraufbereitungs-Industrie. Die ET 200SP in Kombination mit der AirLINE SP, Typ 8647 der Firma Bürkert stellt eine universelle Schnittstelle zwischen Prozess- und Anlagensteuerung dar und ermöglichen den modularen und flexiblen Aufbau von Pilotventilen und I/O-Modulen.
Die Ventilinsel kann außerdem mit Hilfe des sogenannten AirLINE Quick Adapters am Schaltschrankboden befestigt werden, wodurch sich der benötigte Bauraum im Schaltschrank weiter reduziert und die pneumatische Installation deutlich vereinfacht.
Nutzen
Das Pneumatik System bietet folgende Vorteile:
Hohe Prozesssicherheit durch den Einsatz von Rückschlagventilen und pneumatischen Einspeisemodulen mit Drucküberwachung
Detaillierte Diagnosen in Klartext, systemweit und via LC-Display auch direkt vor Ort
Einfacher und schneller Wechsel der Ventile im laufenden Betrieb (Hot Swapping)
Reduzierte Komponenten im Schaltschrank (kompakter Schaltschrank möglich)
Schnelle Installation & Konfiguration der pneumatischen Anschlüsse
Weitere Informationen
Für nähere Informationen zur AirLINE SP, Typ 8647(wie z.B. Datenblatt & Bedienungsanleitung ) wenden Sie sich bitte direkt an die Fa. Bürkert:
Haftungsausschluss:
Diese Informationen und Beschreibungen wurden mit großer Sorgfalt zusammengestellt. Eine Überprüfung der Vollständigkeit, Richtigkeit, und Aktualität der von den Product Partnern gelieferten Daten ist Siemens jedoch nicht möglich. Es ist daher nicht ausgeschlossen, dass einzelne Daten unrichtig, unvollständig oder nicht aktuell sind. Dieser Beitrag enthält Adressen von Webseiten Dritter. Siemens übernimmt für die Inhalte dieser Webseiten weder eine Verantwortung, noch macht Siemens sich diese Webseiten und ihre Inhalte zu eigen, da Siemens die dort dargestellten Informationen nicht kontrolliert und für die dort bereit gehaltenen Inhalte und Informationen auch nicht verantwortlich ist. Deren Nutzung erfolgt auf eigenes Risiko des Nutzers.
1-phasige SITOP Stromversorgungen für SIMATIC ET 200SP
Die 1-phasigen Netzgeräte ermöglichen die optimale Laststromversorgung für die dezentrale Peripherie SIMATIC ET 200SP. Durch ihre extrem flache Bauweise eignen sie sich für den Einbau in 80 mm tiefe Schaltkästen. Durch einen integrierten Strommonitor, eine Betriebs-LED-Anzeige und einen Meldekontakt für „Ausgangsspannung o.k.“ unterstützen sie das Energiemanagement und die Diagnose bei der Anlagenüberwachung. Zudem werden Inbetriebnahme und Wartung vereinfacht, da sich einzelne Lastkreise abkoppeln lassen, 24 Volt aus- und eingeschaltet werden kann und eine Kompensation von Spannungsabfällen bei großen Leitungslängen möglich ist.
Kontakt
Der direkte Weg zu Ihrem SIMATIC ET 200SP Ansprechpartner
Sie haben noch Fragen zu unsere SIMATIC ET 200SP Systemen? Sie möchten mit uns über Ihre konkreten Herausforderungen sprechen oder suchen einen kompetenten Partner für Ihr Projekt? Dann kontaktieren Sie Ihre regionalen Ansprechpartner – wir freuen uns auf Ihre Anfrage