Since the IEC 61508 and IEC 61511 standards for functional safety came into effect, demand has increased for process instrumentation and analytics devices conforming to the Safety Integrity Level (SIL) classification. You can find all the important information about our SIL-related products here: Deliverable Products, Manufacturer Certificates, Safety Manuals and additional information brochures and links for the topic of Functional Safety.
Download brochure
General Information:
Webpage with information regarding Industry Automation: "Systematic Industrial Safety Technology: Safety Integrated"
Detailed information including an overview of the data for functional safety is available in the "Overview of available SIL products".
The following tables show the available SIL-products:
Process Instrumentation
Safety Related Output
|
Safety Function / Measurement of
|
SIL
|
Architecture
|
Declaration
|
Certificate,
Report |
Safety Manual
|
Manual
|
|
---|---|---|---|---|---|---|---|---|
SITRANS P310
analog/HART - C20 |
4…20 mA
|
Pressure
|
SIL 2
|
(1oo1)
|
see manual
|
|||
SITRANS P310
analog/HART - C23 |
4…20 mA
|
Pressure
|
SIL 2/3
|
(1oo1/1oo2)
|
see manual
|
|||
SITRANS P DS III /P410
analog/HART - C20 |
4…20 mA
|
Pressure
|
SIL 2
|
(1oo1)
|
see manual
|
|||
SITRANS P DS III /P410
analog/HART - C23 |
4…20 mA
|
Pressure
|
SIL 2/3
|
(1oo1/1oo2)
|
see manual
|
|||
SITRANS P320/P420 - C20
|
4…20 mA
|
Pressure, Flow, Level
|
SIL 2/3 EN50156-2 |
(1oo1/1oo2) (1oo2) |
see manual
|
|||
SITRANS P DS III PA,
PROFIsafe - C21 |
Digital value and quality
|
Pressure
|
SIL 2
|
(1oo1)
|
see manual
|
|||
SITRANS P500
analog/HART - C20 |
4…20 mA
|
Pressure
|
SIL 2
|
(1oo1)
|
see manual
|
|||
Diaphragm seals connected to
P310 / P DS III / P410- C20/23 |
|
Pressure
|
|
|
|
|
|
|
Diaphragm seals connected to
P320/P420 - C20 |
|
Pressure
|
|
|
|
|
|
Safety Related Output
|
Safety Function / Measurement of
|
SIL
|
Architecture
|
Declaration
|
Certificate,
Report |
Safety Manual
|
Manual
|
|
---|---|---|---|---|---|---|---|---|
|
||||||||
SITRANS TH200/TH300,
HW-Version 01.00 / 01.02 - C20 / C23 |
4…20 mA
|
Temperature
|
SIL 2/3
|
(1oo1/1oo2)
|
see manual
|
|||
SITRANS TH320/TH420/ - C20
|
4…20 mA
|
Temperature
|
SIL 2/3
|
(1oo1/1oo2)
|
||||
|
||||||||
SITRANS TR200/TR300, HW-Version 01.00 / 01.02 - C20 / C23 |
4…20 mA
|
Temperature
|
SIL 2/3
|
(1oo1/1oo2)
|
||||
SITRANS TR320/TR420 - C20
|
4…20 mA
|
Temperature
|
SIL 2/3
|
(1oo1/1oo2)
|
||||
|
||||||||
SITRANS TF with TH200 / TH300, HW-Version 01.00 / 01.02 - C20 / C23 |
4…20 mA
|
Temperature
|
SIL 2/3
|
(1oo1/1oo2)
|
see manual
|
|||
SITRANS TF320/TF420 - C20
|
4…20 mA
|
Temperature
|
SIL 2/3 EN50156-2 |
(1oo1/1oo2) (1oo2) |
||||
|
|
|
|
|
|
|
|
|
SITRANS TS500 with TH320/TH420 - C20
|
4…20 mA
|
Temperature
|
SIL 2/3 EN50156-2 |
(1oo1/1oo2) (1oo2) |
Safety Related Output
|
Safety Function / Measurement of
|
SIL
|
Architecture
|
Declaration
|
Certificate, Report
|
Safety Manual
|
Manual
|
|
---|---|---|---|---|---|---|---|---|
|
||||||||
SITRANS F M MAG 5000 (with Flow Sensor MAG 1100 / 3100 / 5100W) |
4…20 mA
|
Flow
|
SIL 1
|
(1oo1)
|
|
See Declaration and Manual
|
||
SITRANS F M MAG 6000 (with Flow Sensor MAG 1100 / 3100 / 5100W) |
4…20 mA
|
Flow
|
SIL 1
|
(1oo1)
|
|
See Declaration and Manual
|
||
SITRANS F M MAG 6000 I (with Flow Sensor MAG 1100 / 3100 / 5100W) |
4…20 mA
|
Flow
|
SIL 1
|
(1oo1)
|
|
See Declaration and Manual
|
||
|
|
|
|
|
|
|
|
|
SITRANS FX330
|
4…20 mA
|
Flow
|
SIL 2/3
|
(1oo1/1oo2)
|
||||
|
|
|
|
|
|
|
|
|
Primary Element SITRANS FPS200 Primary Element Measurement System SITRANS FP230 |
4…20 mA
|
|
SIL 2/3
|
(1oo1/1oo2)
|
|
See Declaration and Manual
|
||
Averaging Pitot Tube SITRANS FPS300 Averaging Pitot Tube Measuring System SITRANS FP330 |
4…20 mA
|
Flow
|
SIL 2/3
|
(1oo1/1oo2)
|
|
See Declaration and Manual
|
Safety Related Output
|
Safety Function / Measurement of
|
SIL
|
Architecture
|
Declaration
|
Certificate,
Report |
Safety Manual
|
Manual
|
|
---|---|---|---|---|---|---|---|---|
|
||||||||
Pointek CLS200
(Standard) |
Relay or solid-state switch
|
Overfill protection
|
SIL 2
|
(1oo1)
|
||||
SITRANS LPS200
|
Relay
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200S Z Two-wire 8/16 mA - C20 |
Current
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200E Z Two-wire 8/16 mA - C20 |
Current
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200H
Z Two-wire 8/16 mA |
Current
|
Level Min/Max
|
SIL 2/3
|
(1oo1/1oo2)
|
|
|||
SITRANS LVL200H
T Transistor (NPN/PNP) |
Transistor (NPN/PNP)
|
Level Min/Max
|
SIL 2/3
|
(1oo1/1oo2)
|
|
|||
SITRANS LVL200H
R Relay |
Relay
|
Level Min/Max
|
SIL 2/3
|
(1oo1/1oo2)
|
|
|||
SITRANS LVL200S C contactless - C20 |
Electronic Switch
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200E C contactless - C20 |
Electronic Switch
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200S R
relay - C20 |
Relay
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200E R
relay - C20 |
Relay
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200S N NAMUR - C20
|
Current Output
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200E N NAMUR - C20
|
Current Output
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200S –
T Transistor (NPN/PNP) – C20 |
Transistor (NPN/PNP)
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS LVL200E –
T Transistor (NPN/PNP) – C20 |
Transistor (NPN/PNP)
|
Level Min/Max
|
SIL 2
|
(1oo1)
|
||||
SITRANS SCSC
8/16 mA |
Current/relay
|
Level Min/Max
|
SIL 2/3
|
(1oo1/1oo2)
|
see Safety Manual
|
|||
SITRANS TCSC
8/16 mA |
Current/relay
|
Level Min/Max
|
SIL 2/3
|
(1oo1/1oo2)
|
see Safety Manual
|
|||
|
||||||||
SITRANS LR250 (HART) - C20
|
4...20 mA
|
Level
|
SIL 2
|
(1oo1)
|
||||
|
||||||||
SITRANS LG240 (Two-wire PFA Insulated)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1)
|
see Declaration
|
|||
SITRANS LG240 (Two-wire Polished Version)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1)
|
see Declaration
|
|||
SITRANS LG250 (Two-wire Coax probe)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1)
|
see Declaration
|
|||
SITRANS LG250 (Two-wire Rod and cable probe)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1)
|
see Declaration
|
|||
SITRANS LG260 (Two-wire Rod and cable probe)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1)
|
see Declaration
|
|||
SITRANS LG270 (Two-wire Rod and cable probe, -20 … +250 °C)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1)
|
see Declaration
|
|||
SITRANS LG270 (Two-wire Coax probe, -20 … +250 °C)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1)
|
see Declaration
|
|||
SITRANS LG270 (Two-wire Rod and cable probe, -196 … +450 °C)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1/1oo2)
|
see Declaration
|
|||
SITRANS LG270 (Two-wire Coax probe, -196 … +450 °C)
|
4...20 mA
|
Level
|
SIL 2/3
|
(1oo1/1oo2)
|
see Declaration
|
Safety Related Output
|
Safety Function / Measurement of
|
SIL
|
Architecture
|
Declaration
|
Certificate, Report
|
Safety Manual
|
Manual
|
|
---|---|---|---|---|---|---|---|---|
SIPART PS2, 4-20 mA with/without HART - C20
|
|
Depressurizing
|
SIL 2
|
(1oo1)
|
see manual
|
|||
SIPART PS2 PA, digital shut down input - C20
|
|
Depressurizing
|
SIL 2
|
(1oo1)
|
see manual
|
|||
SIPART PS2 FF, digital shut down input - C20
|
|
Depressurizing
|
SIL 2
|
(1oo1)
|
see manual
|
Process Analytics
Safety Related Output
|
Safety Function / Measurement of
|
SIL
|
Architecture
|
Declaration
|
Certificate, Report
|
Safety Manual
|
Manual
|
|
---|---|---|---|---|---|---|---|---|
OXYMAT 6 OXYMAT 6 - C20 |
4...20 mA
|
Concentration
|
SIL 1 SIL 2 |
(1oo1)
|
||||
OXYMAT 61 - C20
|
4...20 mA
|
Concentration
|
SIL 2
|
(1oo1)
|
||||
ULTRAMAT 6 ULTRAMAT 6 - C20 |
4...20 mA
|
Concentration
|
SIL 1 SIL 2 |
(1oo1)
|
||||
CALOMAT 6 CALOMAT 6 - C20 |
4...20 mA
|
Concentration
|
SIL 1 SIL 2 |