Power quality recorder

SICAM Q200
SICAM Q200 is a network analyzer for high-definition acquisition and assessment of the power quality in electrical power supply systems. It offers algorithms and functions for energy management applications. The device supports continuous acquisition and analysis of all relevant parameters. These results help to identify and implement quality programs to ensure the supply quality.
Features & functions
The use of SICAM Q200 increases the service life of the equipment while at the same time reducing downtimes. SICAM Q200 is a PQ device Class A acc. to IEC 62586-1/2 and IEC 61000-4-30 Ed. 3 beyond Class A and acquires, visualizes, analyzes and transmits alternating current characteristics such as current, voltage, frequency, performance, harmonic, etc. The measured variables can be provided to a PC, an energy automation/SCADA system and/or shown on a display using communication interfaces. In addition, the SICAM Q200 provides a combined recording and analysis function for measured values directly in the device. Long-term data and events can be transferred to SICAM PQS / PQ Analyzer System via IEC 61850, and flexible analyses and reports (e.g. EN 50160) can be generated.Applications
Continuous Monitoring of Supply Quality
One of the most frequent causes of unplanned downtimes and device failures is the insufficient quality of the supplied electrical energy. The acquisition and documentation of parameters relevant to supply quality is an important step to identify possible weak points and initiate appropriate measures to eliminate them.
Application
SICAM Q200 is used in single-phase as well as in three-wire and four-wire systems (with neutral conductor) in power utilities, industries, data centers and in commerce.
Examples for:
Technical specification
Network analyzer class A according to IEC 62586-1/2 and IEC 61000-4-30 Ed. 3 beyond class A and meets the measurement accuracy class 0.1S according to IEC 62053-22.
Input Measuring Circuits
- 4x alternating voltage, 4x alternating current
Binary Inputs / Outputs
- Up to 6 inputs, 6 outputs, individually programmable
Memory
- 2 GB sufficient for PQ data according to EN 50160 of several months (expandable)
Measured Characteristics and Power Quality
- Measurement compliant with IEC 61000-4-30 Class A Ed. 3, reporting and analyses compliant with EN 50160 (CBEMA)
- True RMS of voltage and current with 8192 sampled values / 10 sampling cycles (sampling rate 40 kHz @50 Hz), voltage transients with a sampling rate of 1 MHz
- Harmonics up to the 63rd harmonic
- Measurement, visualization, recording in PQDIF of frequencies in the range of
2 kHz to 9 kHz (IEC 61000-4-7) and
9 kHz to 150 kHz (IEC610000-4-30- 2015) - Rapid voltage changes
- Power of harmonics for harmonic direction detection
- Active, reactive and apparent power and energy
- Phase angles
Energy Management
- Load profile peaks and average values; time of use (TOU) with 8 tariffs
- Complies with the following standards: IEC 62053-22 accuracy class 0.2 S, ANSI C12.20 Class 0.2
- ANSI C12.20 Electricity meter, accuracy class 0.2
- 4 Quadrant Power: received and delivered / inductive and capacitive
Data Export
- PQDIF data compliant with IEEE 1159.3, for PQ recordings
- CSV data, e.g. for further processing in MS Excel
- COMTRADE data compliant with IEC 60255-24 / IEEE standard C37.111 for waveform records
Communication Interfaces, Protocols and I/Os
- 2 x Ethernet (IEC61850, DNPP 3i and Modbus TCP), Modbus gateway/master, integrated switch, SNMPv3
- Modbus RTU master and gateway function for RS485 devices
Cybersecurity
- Role-based access control (RBAC): password protection against unauthorized usage, central user management
- Secured and protected communication via IEC 61850 protocol, Web browser communication via https
- Firmware signature: only firmware signed by Siemens will be loaded
- Security log: non-volatile storage of SYSLOG events
Operation and Display
- Graphic display including operation via 4 function keys
- Integrated web server to interact with PC and HTML pages
Time Synchronization
- Ethernet: NTP client (Network Time Protocol)
Auxiliary Voltage
- AC / DC 100 V to 230 V
Housing Specification
- Dimensions: 192 x 96 x 134.6 mm (W / H / D)
- IP54 / NEMA12 option
Special Features
- PQ reporting according to EN 50160 and CBEMA directly over HTML web server
- Visualization of measured Harmonic emissions from 2 kHz to 9 kHz and from 9 kHz to 150 kHz in HTML pages as heat map
- Evaluation of events directly in HTML via COMTRADE viewer/SIGRA plug-in
Customer benefit
The SICAM Q200 is used in the single-phase grid as well as in three-wire and four-wire systems (with neutral) in power
supply utilities, industries, data centers and in commerce.
- Time and cost savings through early identification of problems in the quality of supply based on comprehensive recording of network parameters
- High investment security through the use, of standards, such as:
• Measurement procedures according to IEC 61000-4-30 Class A Ed.3
- guarantee manufacturer-independent comparable measured values
• Standard interfaces and standard protocols (IEC 61850, DNP 3i and Modbus TCP) and data exchange formats (PQDIF, COMTRADE and CSV) - guarantee interoperability - Wide range of applications thanks to the high measurement accuracy and the wide measurement range for high- requency disturbances (2 to 150 kHz and transients with 1 MHz)