Here is a fact: no drive system offers a greater number and variety of functionality than the SINAMICS family. Below you will find which products do what at which level. If you are wondering whether a drive will do something you need, but don't see that function listed for that drive, contact us – it might very well be possible. or we might have missed something.
Contact your local Siemens distributor or sales office
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BICO technology
|
✔
|
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
|
|
✔
|
✔
|
✔
|
Drive control chart (DCC)
|
|
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
Free function blocks
|
|
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
|
|
✔
|
✔
|
✔
|
Integrated connection / application macros
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Motion control capability
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Motor identification
|
|
|
|
✔
|
|
|
|
|
|
|
|
|
|
Numeric control capability
|
|
|
|
|
|
|
|
|
|
|
|
|
|
One-button tuning
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Optimized closed-loop control
|
|
|
|
|
✔
|
|
|
✔
|
|
|
|
|
✔
|
Parameter cloning
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
PID controller
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Positioning capabillity
|
|
|
|
|
✔
|
|
✔
|
✔
|
|
|
|
|
✔
|
Ramp-function generator
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
SINAMICS technology extensions
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Technology controller
|
|
✔
|
|
|
✔
|
|
✔
|
✔
|
|
|
✔
|
✔
|
✔
|
Timestamp for fault and alarm reports
|
|
|
|
|
✔
|
|
|
|
✔
|
✔
|
|
|
|
Vdc max controller
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Web server / Smart Access
|
✔
|
|
|
✔
|
✔
|
✔
|
|
|
✔
|
✔
|
|
|
✔
|
High performance & servo drives
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed |
SINAMICS S150
Enclosed |
---|---|---|---|---|---|---|---|
BICO technology
|
|
|
✔
|
|
|
✔
|
✔
|
Drive control chart (DCC)
|
|
|
✔
|
|
|
✔
|
✔
|
Free function blocks
|
|
|
✔
|
|
|
✔
|
✔
|
Integrated connection / application macros
|
|
|
|
|
|
|
|
Motion control capability
|
|
|
✔
|
|
|
|
|
Motor identification
|
|
|
✔
|
|
|
|
|
Numeric control capability
|
|
|
✔
|
✔
|
|
|
|
One-button tuning
|
|
✔
|
|
|
|
|
|
Optimized closed-loop control
|
|
|
|
|
|
|
|
Parameter cloning
|
|
|
|
|
|
|
|
PID controller
|
|
|
|
|
|
|
|
Positioning capabillity
|
|
|
✔
|
|
|
|
|
Ramp-function generator
|
|
|
✔
|
|
|
|
|
SINAMICS technology extensions
|
|
|
✔
|
|
|
|
|
Technology controller
|
|
|
✔
|
|
|
|
✔
|
Timestamp for fault and alarm reports
|
|
|
✔
|
|
|
|
|
Vdc max controller
|
|
|
|
|
|
|
|
Web server / Smart Access
|
|
✔
|
✔
|
|
|
|
|
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Brake control
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Compound braking
|
|
|
|
|
✔
|
✔
|
|
✔
|
✔
|
|
|
|
✔
|
Control for motor holding and operating brake
|
|
✔
|
|
|
|
|
|
|
|
|
|
|
|
DC braking
|
|
|
|
|
✔
|
✔
|
|
✔
|
✔
|
|
|
|
✔
|
Dynamic braking
|
|
|
|
|
✔
|
✔
|
|
✔
|
✔ *
|
|
|
|
✔
|
Software braking technique
|
|
|
✔
|
|
|
|
|
|
|
|
|
|
✔
|
High performance & servo drives
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed |
SINAMICS S150
Enclosed |
---|---|---|---|---|---|---|---|
Brake control
|
✔
|
|
✔
|
|
|
|
|
Compound braking
|
|
|
|
|
|
|
|
Control for motor holding and operating brake
|
✔
|
|
|
|
|
|
|
DC braking
|
|
|
|
|
|
|
|
Dynamic braking
|
|
|
|
|
|
|
|
Electrical brakes (is this a function?)
|
|
|
|
|
|
|
|
Software braking technique
|
|
|
|
|
|
|
|
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Automatic restart
|
|
✔
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Bypass mode
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Cascading
|
✔
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Dual Ramp
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Flying restart
|
|
✔
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Jog mode
|
|
✔
|
|
|
|
|
|
|
|
|
|
|
|
Keep-Running mode
|
✔
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Kinetic buffering
|
|
|
|
|
✔
|
✔
|
|
✔
|
|
|
✔
|
✔
|
✔
|
Limit switch function
|
|
|
✔
|
|
|
|
|
|
|
|
|
|
|
Motor and machine encoder evaluation
|
|
|
|
|
|
|
✔
|
|
|
|
|
|
|
Multi-pump
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Multispeed setpoints
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Pump switchover
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Quick stop
|
|
✔
|
✔
|
|
|
|
|
|
|
|
|
|
|
Real-time clock for autonomous, time-controlled operation
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Setpoint input
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Skipping critical motor speeds
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
High performance & servo drives
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed |
SINAMICS S150
Enclosed |
---|---|---|---|---|---|---|---|
Automatic restart
|
|
|
✔
|
|
|
✔
|
✔
|
Bypass mode
|
|
|
|
|
|
|
|
Cascading
|
|
|
|
|
|
|
|
Dual Ramp
|
|
|
|
|
|
|
|
Flying restart
|
|
|
✔
|
|
|
✔
|
✔
|
Jog mode
|
|
|
|
|
|
|
|
Keep-Running mode
|
|
|
|
|
|
|
|
Kinetic buffering
|
|
|
✔
|
|
|
✔
|
✔
|
Limit switch function
|
|
|
|
|
|
|
|
Motor and machine encoder evaluation
|
|
|
|
|
|
|
|
Multi-pump
|
|
|
|
|
|
|
|
Multispeed setpoints
|
|
|
|
|
|
|
|
Pump switchover
|
|
|
|
|
|
|
|
Quick stop
|
|
|
|
|
|
|
|
Real-time clock for autonomous, time-controlled operation
|
|
|
|
|
|
|
|
Setpoint input
|
|
|
✔
|
|
|
|
|
Skipping critical motor speeds
|
|
|
|
|
|
|
|
Many more energy functions are discussed in detail on the Drives Energy Efficiency page.
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ECO mode
|
✔
|
|
|
|
✔
|
✔
|
|
✔
|
✔
|
✔
|
|
|
|
Energy / flow calculator
|
|
|
|
|
✔
|
|
|
✔
|
✔
|
✔
|
|
|
|
Energy exchange
|
✔
|
|
|
|
|
|
|
|
|
|
|
|
|
Hibernation mode
|
✔
|
|
|
|
✔
|
✔
|
|
|
✔
|
✔
|
|
|
|
Power regenration
|
|
|
|
|
✔
|
|
✔
|
✔
|
|
|
|
|
|
Programmable timer
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
High performance & servo drives
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed |
SINAMICS S150
Enclosed |
---|---|---|---|---|---|---|---|
ECO mode
|
|
|
|
|
|
|
|
Energy / flow calculator
|
|
|
|
|
|
|
|
Energy exchange
|
|
|
|
|
|
|
|
Hibernation mode
|
|
|
|
|
|
|
|
Power regeneration
|
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
Programmable timer
|
|
|
|
|
|
|
|
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Detection of communication bus interruption
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Detection of missing communication telegrams
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Drive overtemperature protection
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
External fault and warning monitoring
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Know-how protection
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Loss of analog input signal monitoring
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Overvoltage controller
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Undervoltage controller
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Write protection
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
High performance & servo drives
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed |
SINAMICS S150
Enclosed |
---|---|---|---|---|---|---|---|
Detection of communication bus interruption
|
|
|
|
|
|
|
|
Detection of missing communication telegrams
|
|
|
|
|
|
|
|
Drive overtemperature protection
|
|
|
|
|
|
|
|
External fault and warning monitoring
|
|
|
|
|
|
|
|
Know-how protection
|
|
|
✔
|
|
|
|
|
Loss of analogue input signal monitoring
|
|
|
|
|
|
|
|
Overvoltage controller
|
|
|
|
|
|
|
|
Undervoltage controller
|
|
|
|
|
|
|
|
Write protection
|
|
|
✔
|
|
|
|
|
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
I2t sensing for motor protection
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Blocking & stalling monitoring and protection
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Motor blocking protection
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Motor overload monitoring and protection
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Motor overtemperature protection
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Motor short circuit and ground fault protection
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Phase-loss detection (for both supply and motor)
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
Speed and torque monitoring
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
High performance & servo drives
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed |
SINAMICS S150
Enclosed |
---|---|---|---|---|---|---|---|
I2t sensing for motor protection
|
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
Blocking & stalling monitoring and protection
|
|
|
|
|
|
|
|
Motor blocking protection
|
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
Motor overload monitoring and protection
|
|
|
|
|
|
|
|
Motor overtemperature protection
|
|
|
✔
|
|
|
|
|
Motor short circuit and ground fault protection
|
|
|
|
|
|
|
|
Phase-loss detection (for both supply and motor)
|
|
|
|
|
|
|
|
Speed and torque monitoring
|
|
|
|
|
|
|
|
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blockage, leakage & dry-running protection
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Cavitation detection
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Condensation protection
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Deragging
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Frost protection
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Multi-pump control
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
No load detection
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Pipe filling
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Service mode
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Stop mode
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Standard performance drives
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed |
Robicon W
Enclosed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Essential service mode
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Multi-fan control
|
|
|
|
|
|
|
|
|
✔
|
✔
|
|
|
|
Selection, system configuration
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed * |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed * |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed * |
Robicon W
Enclosed * |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔ **
|
✔
|
✔ **
|
✔
|
✔ **
|
✔ **
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔ **
|
✔
|
✔ **
|
✔
|
✔ **
|
✔ **
|
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔ **
|
✔
|
✔ **
|
✔
|
✔ **
|
✔ **
|
|
✔
|
|
|
|
✔
|
✔
|
|
✔ **
|
✔
|
✔ **
|
|
|
|
* Note that for custom-engineered enclosed drives, selection tools will vary in ability to configure the actual product.
** Pertains to drive enclosed in the cabinet.
Commissioning, engineering
Click headings >
to visit product page (scroll to the right to see all drives) |
SINAMICS V20
Compo- nent |
SINAMICS G110D
Distrib- uted |
SINAMICS G110M
Distrib- uted |
SINAMICS G115D
Distrib- uted |
SINAMICS G120
Compo- nent |
SINAMICS G120C
Compo- nent |
SINAMICS G120D
Distrib- uted |
SINAMICS G120E
Enclosed * |
SINAMICS G120X
Compo- nent |
SINAMICS G120XE
Enclosed * |
SINAMICS G130
Compo- nent |
SINAMICS G150
Enclosed * |
Robicon W
Enclosed * |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
On-drive
|
✔
|
✔ (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
✔** (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
✔ (op. panel)
|
Remote Access / web-server
|
✔
|
|
|
✔
|
✔
|
✔
|
|
|
✔
|
✔
|
|
|
|
|
✔
|
✔
|
|
✔
|
✔
|
✔
|
|
|
|
✔
|
✔ **
|
✔ **
|
|
Startdrive (TIA Portal)
|
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔ **
|
|
|
✔
|
✔ **
|
✔ **
|
* Note that for custom-engineered enclosed drives, selection tools will vary in ability to configure the actual product.
** Pertains to drive enclosed in the cabinet.
Selection, system configuration
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed * |
SINAMICS S150
Enclosed * |
---|---|---|---|---|---|---|---|
✔
|
✔
|
✔
|
✔
|
✔
|
✔ **
|
✔ **
|
|
✔
|
✔
|
✔
|
✔
|
✔
|
✔ **
|
✔ **
|
|
|
|
✔
|
|
|
|
|
|
|
✔
|
|
|
|
|
|
* Note that for custom-engineered enclosed drives, selection tools will vary in ability to configure the actual product.
** Pertains to drive enclosed in the cabinet.
Commissioning, engineering
Click headings >
to visit product page |
MICRO-DRIVE
Component |
SINAMICS S210
Component |
SINAMICS S120
Component |
SINAMICS S120M
Distributed |
SINAMICS S120-combi
Component |
SINAMICS S120 CM
Enclosed * |
SINAMICS S150
Enclosed * |
---|---|---|---|---|---|---|---|
On-drive
|
|
|
|
configured in drive
|
|
✔ (op. panel)
|
✔ (op. panel)
|
Remote Access / web-server
|
|
✔
|
✔
|
configured in drive
|
✔
|
✔ **
|
✔ **
|
|
|
✔
|
configured in drive
|
✔
|
✔ **
|
✔ **
|
|
Startdrive (TIA Portal)
|
✔
|
✔
|
✔
|
configured in drive
|
✔
|
✔ **
|
✔ **
|
* Note that for custom-engineered enclosed drives, selection tools will vary in ability to configure the actual product.
** Pertains to drive enclosed in the cabinet.