Maybe you know exactly what to look for in choosing a drive – you just need to figure out which Siemens drive will do the job. This page is for you – listing the drives that operate at what voltage, horsepower, on which communications protocols, and those many sorts of things.

Ratings

Select drives by the most common specifications

For precise voltage / power ratings at each voltage, visit the product's page (click link in column head).

* with derated output
Voltages
SINAMICS V20
for basic applications
SINAMICS G120
modular vector
SINAMICS G120C
compact vector
SINAMICS G120X
for pumps, fans, compressors
SINAMICS G130
for higher-horsepower
• 1AC 200 - 240V
 
✔ *
 
• 3AC 200 - 240V
 
 
• 3AC 380 - 480V
• 1AC 440 - 480V
 
 
 
✔ *
 
• 3AC 500 - 690V
 
 
• 3AC 660 - 690V
 
 
 
 
 
SINAMICS V20
for basic applications
SINAMICS G120
modular vector
SINAMICS G120C
compact vector
SINAMICS G120X
for pumps, fans, compressors
SINAMICS G130
for higher-horsepower
Power range
 - Hp (kW)
0.16 - 40 (0.12 - 30)
0.75 - 400 (0.55 - 250)
0.75 - 150 (0.55 - 132)
1 - 700 (0.75 - 630)
150 - 1100 (110 - 800)
Click column headings >
to visit product page
SINAMICS G110M
Gearmotor mounted
SINAMICS G15D
for horizontal motion
Voltage
3AC 380 - 480V
3AC 380 - 480V
3AC 380 - 480V
3AC 380 - 480V
Power range - Hp (kW)
1 - 10 (0.75 - 7.5)
0.5 - 5 (0.37 - 4)

Motor-mounted: 0.5 – 5  (0.37 – 4)

Wall-mounted: 0.5 – 10  (0.37 – 7.5)

1 - 10 (0.75 - 7.5)

For precise voltage / power ratings at each voltage, visit the product's page (click link in table head).

Voltages
SINAMICS G120XE
for pumps, fans, compressors
SINAMICS G150
higher horsepower
Robicon W
for municipal water/wastewater
• 1AC 200 - 240V
 
 
 
• 3AC 200 - 240V
 
 
 
• 3AC 380 - 480V
✔ (opt.)
 
• 3AC 460 - 480V
 
 
• 3AC 500 - 690V
 
 
• 3AC 660 - 690V
 
 
 
 
 
SINAMICS G120XE
for pumps, fans, compressors
SINAMICS G150
higher horsepower
Robicon W
for municipal water/wastewater

Power range
 - Hp (kW)
1 – 200 Hp (0.75 -–132 KW)
1 – 200 Hp (0.75 -–132 KW)
150 – 800 Hp (110 – 560 kW)
1 – 200 Hp (0.75 -–132 KW)

For precise voltage / power ratings at each voltage, visit the product's page (click link in table head).

Voltages
MICRO-DRIVE
Component
SINAMICS S210
Component
SINAMICS S120
Component
SINAMICS S120M
Distributed
SINAMICS S120-combi
Component
SINAMICS S150
Enclosed
24 - 48V DC
 
 
 
 
 
 
510 - 720V DC
 
 
 
 
 
 
• 1AC 200 - 240V
 
 
 
 
 
• 3AC 200 - 240V
 
 
 
 
 
 
 
• 3AC 380 - 480V
 
 
• 3AC 460 - 480V
 
 
 
 
 
✔ (NEMA to 600V)
✔ (NEMA to 600V)
• 3AC 500 - 690V
 
 
 
 
 
 
 
MICRO-DRIVE
Component
SINAMICS S210
Component
SINAMICS S120
Component
SINAMICS S120M
Distributed
SINAMICS S120-combi
Component
SINAMICS S150
Enclosed
Power range - Hp (kW) 2
100 – 1,000W
0.13 - 10 (0.05 - 7.5)
0.16 - 1,600 (0.12 - 1,200)
0.3 - 2 (0.25 - 1.5)
0.75 - 150 (0.55 - 20 - 55 (16 - 40)
150 - 1,250 (110 - 950)
150 - 1,250 (110 - 950)

Standard performance drives


Click column headings >
to visit product page
(scroll to the right to see all drives)
SINAMICS V20
Compo-
nent
SINAMICS G110D
Distrib-
uted
SINAMICS G110M
Distrib-
uted
SINAMICS G115D
Distrib-
uted
SINAMICS G120
Compo-
nent
SINAMICS G120C
Compo-
nent
SINAMICS G120D
Distrib-
uted
SINAMICS G120X
Compo-
nent
SINAMICS G130
Compo-
nent
SINAMICS G150
Enclosed
Robicon W
Enclosed
General
Linear
Parabolic
User-defined
Flux Current Control (FCC)
ECO linear/parabolic (ECO mode)

High performance & servo drives


Click column headings >
to visit product page
(scroll to the right to see all drives)
MICRO-DRIVE
Component
SINAMICS S210
Component
SINAMICS S120
Component
SINAMICS S120M
Distributed
SINAMICS S120-combi
Component
SINAMICS S150
Enclosed
General
with linear characteristic
with parabolic characteristic
with user-defined characteristic
with Flux Current Control (FCC)
ECO linear/parabolic (ECO mode)

Standard performance drives


Click column headings >
to visit product page
(scroll to the right to see all drives)
SINAMICS V20
Compo-
nent
SINAMICS G110D
Distrib-
uted
SINAMICS G110M
Distrib-
uted
SINAMICS G115D
Distrib-
uted
SINAMICS G120
Compo-
nent
SINAMICS G120C
Compo-
nent
SINAMICS G120D
Distrib-
uted
SINAMICS G120X
Compo-
nent
SINAMICS G130
Compo-
nent
SINAMICS G150
Enclosed
Robicon W
Enclosed
Sensorless (SLVC)
With encoder
✔*
✔*
✔*
Droop
✔*
✔*
✔*
Speed controller adaption
✔*
✔*
✔*
Speed controller precontrol and reference model
✔*
✔*
✔*
Open actual speed value
✔*
✔*
✔*
Current setpoint filter
Speed actual value filter
Current controller adaption
✔*
✔*
✔*
Fast magnetization for induction motors
✔*
✔*
✔*
Synchronization (motor to grid)
Simulation mode
Redundancy mode power units
Bypass with synchronization with overlap
Bypass with synchronization without overlap
Bypass without synchronization
✔*
✔*
✔*
Asynchronous pulse frequency
Autom. controller tuning vector
Precontrol
I/f open-loop control with constant current
✔* (only for diagnosis)
✔* (only for diagnosis)
Encoderless closed-loop up to standstill
Click column headings >
to visit product page
(scroll to the right to see all drives)
SINAMICS V20
Compo-
nent
SINAMICS G110D
Distrib-
uted
SINAMICS G110M
Distrib-
uted
SINAMICS G115D
Distrib-
uted
SINAMICS G120
Compo-
nent
SINAMICS G120C
Compo-
nent
SINAMICS G120D
Distrib-
uted
SINAMICS G120X
Compo-
nent
SINAMICS G130
Compo-
nent
SINAMICS G150
Enclosed
Robicon W
Enclosed
 
 
Click column headings >
to visit product page
MICRO-DRIVE
Component
SINAMICS S210
Component
SINAMICS S120
Component
SINAMICS S120M
Distributed
SINAMICS S120-combi
Component
SINAMICS S150
Enclosed

Click column headings to visit product page

Click communications protocol for more details * Communications within the scope of Siemens Totally Integrated Automation (TIA)
Communications protocol
SINAMICS V20
for basic applications
SINAMICS G120
modular vector
SINAMICS G120C
compact vector
SINAMICS G120X
for pumps, fans, compressors
SINAMICS G130
for higher-horsepower
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Click column headings to visit product page

Click communications protocol for more details * Communications within the scope of Siemens Totally Integrated Automation (TIA)
Communications protocol
SINAMICS G110M
Gearmotor mounted
SINAMICS G115D
for horizontal motion
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Click column headings to visit product page

Click communications protocol for more details * Communications within the scope of Siemens Totally Integrated Automation (TIA)
Communications protocol
SINAMICS G120XE
for pumps, fans, compressors
SINAMICS G150
higher horsepower
Robicon W
for municipal water/wastewater
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Click column headings to visit product page

Click communications protocol for more details * Communications within the scope of Siemens Totally Integrated Automation (TIA)
Communications protocol
MICRO-DRIVE
Component
SINAMICS S210
Component
SINAMICS S120
Component
SINAMICS S120M
Distributed
(communications from S120 CU)
SINAMICS S120-combi
Component
SINAMICS S150
Enclosed
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Standard performance drives - component
Click headings >
to visit product page
SINAMICS V20
for basic applications
SINAMICS G120
modular vector
SINAMICS G120C
compact vector
SINAMICS G120X
for pumps, fans, compressors
SINAMICS G130
for higher-horsepower
IP
IP20

IP20

(IP21 with wall mount kits)

IP20

(IP21 with wall mount kits)

IP20

IP20: protected chassis for ratings up to 400 HP (298 KW) at 490A

IP00:  above 400 Hp in an open chassis design

 UL
Open type

Open Type

(UL Type 1 with wall mount kits)

Open Type

(UL Type 1 with wall mount kits)

Open type
 
Standard performance drives – distributed
Click headings >
to visit product page
SINAMICS G110M
Gearmotor mounted
SINAMICS G115D
for horizontal motion
IP
IP65
Up to IP66

Motor-mounted: IP55 (limited by motor) or optional IP65 / UL rating follows geared motor (compact system)

Wall-mounted: IP65 (connected version) or AP66 (gland version) / IP66

IP65
Standard performance drives - enclosed
Click headings >
to visit product page
SINAMICS G120XE
for pumps, fans, compressors
SINAMICS G150
higher horsepower
Robicon W
for municipal water/wastewater
NEMA 1 - standard
 NEMA 12 - ventilated
opt.
opt.
opt.
opt.
IEC
 
 
 
High performance & servo drives
Click headings >
to visit product page
MICRO-DRIVE
Component
SINAMICS S210
Component
SINAMICS S120
Component
SINAMICS S120M
Distributed
SINAMICS S120-combi
Component
SINAMICS S150
Enclosed
IP
IP20
IP20
AC/AC blocksize: IP65
AC/AC chassis: IP20, IP43 opt.
AC/DC booksize: IP00, IP20
IP65 with IP67 shaft seal ring
IP20
IP20, IP21 / IP23, IP43 / IP54
IP20, IP21 / IP23, IP43 / IP54
NEMA
 
 
 
 
 
 
 
Click headings >
to visit product page
SINAMICS V20
for basic applications
SINAMICS G120
modular vector
SINAMICS G120C
compact vector
SINAMICS G120X
for pumps, fans, compressors
SINAMICS G130
for higher-horsepower
China Compulsory Certification (CCC)
 
 
 
 
CE
 cULus
RCM (formerly c-Tick)
 
KCC
 
 
 
WEEE
 
 
 
 
 
RoHS
 
 
 
 
EAC
 
 
 
 
EN
 
 
 
REACH
 
 
 
 
SEMI F47
 
 
 
UKCA
✔ *
✔ *
✔ *
✔ *
✔ *
Safety **
STO, SS1, SBC, SLS, SSM, SDI
STO
SIL3 STO
STO, SS1, SBC, SLS, SSM, SDI

* All SINAMICS component drives are in the process of becoming UKCA compliant

** More details on SINAMICS Safety Integrated

Click headings >
to visit product page
SINAMICS G110M
Gearmotor mounted
SINAMICS G115D
for horizontal motion
CE
 cULus
RCM (formerly c-Tick)
KCC
 
 
 
EAC
 
 
 
REACH
 
 
 
SEMI F47
 
 
 
Safety*
STO
STO
STO
STO, SS1, SBC, SLS, SSM, SDI

* More details on SINAMICS Safety Integrated

Click headings >
to visit product page
SINAMICS G120XE
for pumps, fans, compressors
SINAMICS G150
higher horsepower
Robicon W
for municipal water/wastewater
CE
 cULus
RCM (formerly c-Tick)
 
 
KCC
 
 
 
RoHS
 
 
 
EAC
 
 
 
EN
 
 
 
REACH
 
 
 
SEMI F47
 
 
Safety*
STO, SS1, SBC, SLS, SSM, SDI
SIL3 STO
STO, SS1, SBC, SLS, SSM, SDI
STO

* More details on SINAMICS Safety Integrated

Click headings >
to visit product page
SINAMICS G120XE
for pumps, fans, compressors
SINAMICS G150
higher horsepower
Robicon W
for municipal water/wastewater
Seismic Certificate (IBC)
 
 
OSHPD pre-certification
 
 
Click headings >
to visit product page
MICRO-DRIVE
Component
SINAMICS S210
Component
SINAMICS S120
Component
SINAMICS S120M
Distributed
SINAMICS S120-combi
Component
SINAMICS S150
Enclosed
CE
 cULus
RCM (formerly c-Tick)
 
 
 
 
 
 
 
Marine
 
 
 
 
 
 
KCC
 
 
 
 
 
 
 
WEEE
 
 
 
 
 
 
 
RoHS
 
 
 
 
 
 
EAC
 
 
 
 
 
 
 
IEC / EN
 
 
REACH
 
 
 
 
 
 
 
SEMI F47
 
 
 
 
 
 
 
Safety*
STO, SS1, SLT, SLS, SSM
STO, SS1, SBC, SLS, SDI, SOS, SS2, SBT, SSM
STO, SS1, SBC, SLS, SDI, SOS, SS2, SBT, SSM, SLP, SPO, SLA, SCA
STO, SS1, SBC, SLS, SDI, SOS, SS2, SBT, SSM, SLP, SPO, SLA, SCA
STO, SS1, SBC, SLS, SDI, SOS, SS2, SBT, SSM, SLP, SPO, SLA, SCA
STO, SS1, SBC, SLS, SDI, SOS, SS2, SBT, SSM, SLP, SPO, SLA, SCA
STO, SS1, SBC, SLS, SDI, SOS, SS2, SBT, SSM, SLP, SPO, SLA, SCA

* More details on SINAMICS Safety Integrated